ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bjortuft, O
Right arrow Articles by Boe, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bjortuft, O
Right arrow Articles by Boe, J
Eur Respir J 1998; 12: 1025-1027
Copyright © ERS Journals Ltd 1998


Original Articles

Bronchoscopy with transbronchial biopsies: measurement of bleeding volume and evaluation of the predictive value of coagulation tests

O Bjortuft, F Brosstad, and J Boe

The objectives of this study were to measure the bleeding volume associated with fibreoptic bronchoscopy with transbronchial biopsies (TBB), to correlate it with coagulation tests and to compare bleeding volume in patients with and without lung transplant. A total of 104 consecutive TBB in 51 different patients was evaluated prospectively. Before each procedure, haemoglobin, blood platelets, prothrombin time (PT), activated partial thromboplastin time (aPTT) and bleeding time were measured. During the procedure, lavage fluid and blood were collected by suction. The haemoglobin concentration of the mixture was measured and bleeding volume was calculated. Clinically significant bleeding was arbitrarily defined as >20 mL blood present in lavage fluid. The mean+/-SD bleeding volume was 7+/-10 mL with no statistically significant difference between transplanted and nontransplanted patients. In eight procedures (7.7%) the bleeding volume was >20 mL (range 22-61 mL). Prebiopsy values for blood platelet counts, PT and aPTT did not predict a bleeding tendency in any of the procedures in which significant bleeding occurred. No correlation was found between bleeding time and bleeding volume in the 17 procedures performed in patients with a prolonged bleeding time (> or =10 min). The bleeding associated with transbronchial biopsies was usually minor and quantitatively similar in patients with or without lung transplant. Coagulation tests could not predict clinically significant bleeding, which may occur in patients with normal coagulation test results.


This article has been cited by other articles:


Home page
ChestHome page
P. N. Chhajed, M. A. Malouf, and A. R. Glanville
Risk of Bleeding Associated With Transbronchial Lung Biopsy
Chest, June 1, 2003; 123(6): 2162 - 2162.
[Full Text] [PDF]


Home page
JCOHome page
C. A. Schiffer, K. C. Anderson, C. L. Bennett, S. Bernstein, L. S. Elting, M. Goldsmith, M. Goldstein, H. Hume, J. J. McCullough, R. E. McIntyre, et al.
Platelet Transfusion for Patients With Cancer: Clinical Practice Guidelines of the American Society of Clinical Oncology
J. Clin. Oncol., March 1, 2001; 19(5): 1519 - 1538.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the European Respiratory Society.