ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bersten, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bersten, A.
Eur Respir J 1998; 12: 526-532
Copyright © ERS Journals Ltd 1998


Clinical Trial

Measurement of overinflation by multiple linear regression analysis in patients with acute lung injury

AD Bersten

Strategies to optimize alveolar recruitment and prevent lung overinflation are central to ventilatory management of patients with acute lung injury (ALI). The recent description of overinflation using multilinear regression analysis of airway pressure (Paw) and flow (V') data allows a functional assessment of lung mechanics. However, this technique has not been studied in ALI patients. During 15 positive end-expiratory pressure (PEEP) trials in 10 ALI patients, respiratory elastance was partitioned into volume-independent (E1) and volume-dependent (E2VT) components, where Paw=(E1+E2VT)V+RrsV'+Po; where V is volume, VT is tidal volume, Rrs is respiratory resistance and Po is static recoil pressure at end-expiration (equivalent to total PEEP). Then, %E2 was calculated as (100E2VT)/(E1+E2VT); a measure of lung overinflation when %E2>30%. Alveolar recruitment, assessed as a PEEP-induced increase in V>50 mL at a constant Paw occurred in 14 of 15 trials (299+/-34 mL, mean+/-SEM), but was independent of the degree of lung inflation. Lung overinflation was common (six of 15 clinically set PEEP levels) and occurred despite a dynamic elastic distending pressure (Pel,dyn) <30 cmH2O during 18 of 36 PEEP titrations. During a PEEP titration the resultant %E2 was directly related to delta(peak airway pressure-Po) (rs=0.86, p<0.001) and delta(Pel,dyn-Po) (rs=0.89, p<0.001). The 95% predictive intervals for a 2 cmH2O change in either driving pressure were %E2 values of 30.4-68.1% and 32.8-69.2%, respectively. Single or continuous measurement of %E2 (a measure of lung inflation) is a readily available method for titrating ventilatory parameters. Further, during a positive end-expiratory pressure titration a change in ventilatory driving pressure > or =2 cmH2O is indicative of overinflation.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. H. T. Bates and C. G. Irvin
Measuring lung function in mice: the phenotyping uncertainty principle
J Appl Physiol, April 1, 2003; 94(4): 1297 - 1306.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. Edibam, A. J. Rutten, D. V. Collins, and A. D. Bersten
Effect of Inspiratory Flow Pattern and Inspiratory to Expiratory Ratio on Nonlinear Elastic Behavior in Patients with Acute Lung Injury
Am. J. Respir. Crit. Care Med., March 1, 2003; 167(5): 702 - 707.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Wagers, L. Lundblad, H. T. Moriya, J. H. T. Bates, and C. G. Irvin
Nonlinearity of respiratory mechanics during bronchoconstriction in mice with airway inflammation
J Appl Physiol, May 1, 2002; 92(5): 1802 - 1807.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
V. Kessler, J. Guttmann, and C.J.L. Newth
Dynamic respiratory system mechanics in infants during pressure and volume controlled ventilation
Eur. Respir. J., January 1, 2001; 17(1): 115 - 121.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
V. NÈVE, E. D. de la ROQUE, F. LECLERC, S. LETEURTRE, A. DORKENOO, A. SADIK, R. CREMER, and R. LOGIER
Ventilator-induced Overdistension in Children . Dynamic versus Low-flow Inflation Volume-Pressure Curves
Am. J. Respir. Crit. Care Med., July 1, 2000; 162(1): 139 - 147.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the European Respiratory Society.