ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barry, P.
Right arrow Articles by O'Callaghan, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barry, P.
Right arrow Articles by O'Callaghan, C
Eur Respir J 1998; 12: 463-466
Copyright © ERS Journals Ltd 1998


Original Articles

Drug output from nebulizers is dependent on the method of measurement

PW Barry and C O'Callaghan

The objective of this study was to determine whether current regulatory methods for assessing the output of nebulizers are appropriate for the delivery of nebulized steroid suspensions to patients. We studied a conventional jet nebulizer (the Intersurgical Cirrus), an open-vent nebulizer (the Medicaid Sidestream) and a breath-enhanced nebulizer (the Pari LC Plus), using a constant sampling flow or a sinusoidal pump to represent the breathing pattern of children from 6 months to adulthood. Recovery of budesonide released from the nebulizers onto filters was reduced when using breathing simulation compared with constant flow, and this reduction was greatest for the conventional nebulizer (Cirrus, 103 microg with constant flow to 4.4 microg with a 50 mL tidal volume; Pari, 176 microg to 25 microg). The open-vent nebulizer deposited very little budesonide on the filter at lower tidal volumes (4.5 microg with a 50 mL tidal volume), possibly because the enhanced flow of aerosol laden air was greater than the inspiratory flow from the breathing simulator. The output of the LC plus was reduced at high flow, from 176 microg at 20 L x min(-1) to 93 microg at 60 L x min(-1). Overall, the measured output varied by up to 700%, depending on the method used. These results suggest that breathing patterns dramatically alter the measured output of different nebulizers and that breathing simulation should be included as part of their assessment.