ERJ
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Eur Respir J 1988; 1:15-21
Copyright ©ERS Journals Ltd 1988

This Article
Right arrow Order Full text via Infotrieve
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Permissions
Right arrowRequest Permissions
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chinn, D.
Right arrow Articles by Cotes, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chinn, D.
Right arrow Articles by Cotes, J.

Original Articles

Measurement technique influences the response of transfer factor (TICO) to salbutamol in patients with airflow limitation

DJ Chinn, J Askew, L Rowley, and JE Cotes

Single-breath transfer factor obtained using a multibreath estimate of alveolar volume (TI) was measured before and after salbutamol in twenty patients with reversible airflow limitation. The effective breathholding time was calculated by four methods due respectively to Ogilvie and colleagues as modified by the American Thoracic Society (ATS), ATS Epidemiological Standardization Project (ESP), Jones and Meade in which allowance was made for the time of sample collection and a simplified method in which the allowance for sampling was in terms of volume, not time. Two patients could perform the test procedure only after salbutamol. Amongst the remainder the transfer factor calculated using a single-breath estimate of alveolar volume (TI') was on average 12% less than TI. Carbon monoxide transfer coefficient (KCO), TI and TI' were highest by the ESP method and lowest by the Ogilvie method. Inhalation of salbutamol (200 gamma) did not affect TI' by any method or TI and KCO by the Jones and Meade method but results by the other methods were reduced; in the case of the modified Ogilvie method the reduction was 3.9%. This error was due to overestimation of effective breathholding time by neglecting the reduction of 39% which occurred in the time of sample collection. The time of inspiration was unchanged whilst the time of deadspace washout was reduced by 16%. After bronchodilatation the absence of a change in TI' was due to the overestimation of effective breathholding time being offset by an increase in the proportion of alveolar volume measured by the single-breath procedure.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Eur Respir JHome page
N. MacIntyre, R. O. Crapo, G. Viegi, D. C. Johnson, C. P. M. van der Grinten, V. Brusasco, F. Burgos, R. Casaburi, A. Coates, P. Enright, et al.
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
Eur. Respir. J., October 1, 2005; 26(4): 720 - 735.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
D. L. SHERRILL, P. L. ENRIGHT, W. T. KALTENBORN, and M. D. LEBOWITZ
Predictors of Longitudinal Change in Diffusing Capacity over 8 Years
Am. J. Respir. Crit. Care Med., December 1, 1999; 160(6): 1883 - 1887.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the European Respiratory Society.